ONE-PACK POLYURETHANE MAINTENANCE PRIMER No 700
Specification Data | |
Type | One-pack,moist curing type of primer that based on polyisocyanate resin with rust inhibitors such as zinc powder. |
Uses | Used for steel structures,harbor facilities,bridges,pipelines |
Characteristics | ˙one-pack packing can result to cost-effectiveness and time saving. ˙Moist curing type of coating can be applied under highly humid environment. ˙Excellent permeability to surface due to low viscosity of coating . It can tightly seal and adhere the steel structure surface and its rusty façade. ˙Suitable to rusty steel surface that can only be cleaned by hand or by high pressure water but is unable to clear by blasting. ˙Excellent chemical and water resistance and weatherability . Qualified by the standard of CNS 10757 K6801 3000hrs salt spray test. ˙Quick drying to shorten application period. |
Color Finish | Brown and Gray Flat |
Service Temperature | 100℃(212℉) |
VOC values Solids Content | 360 g/L. By Weight Above 85% |
Zinc Content in Dry Film | By Weight Above 70% |
Theoretical Coverage | 38.0 m2/Gal (409 ft2/Gal)10.0 m2/L (107.6 ft2/L)4.6 m2/Kg (49.5 ft2/Kg)( DFT :2.4 mils) |
Dry Film Thickness | Dry:2.4milsWet:4mils |
Preceding Coats | Polyurethane、Epoxy and Fluorine Topcoating. |
Repair | itself |
Application Instruction
˙Surface preparation
General | Remove dirt, dust, oil and all other contaminants that could interfere with adhesion of the coating. Surfaces must be clean and dry. Moisture, grease, sludge, dust, corrosive salt must be thoroughly cleaned from substrate. |
Steel
Areas of Breakdown and Damage | Surface preparation standards can use SSPC-SP10 or Sa2 1/2 (ISO 8501-1:2007). It should be prepared to the specified standard (Sa2 1/2 (ISO 8501-1:2007) or SSPC-SP6, Abrasive Blasting or SSPC-SP11, Power Tool Cleaning) and patch primed prior to the application of No.700. |
˙Mixing & Thinning
Mixing Thinning | Use No.736 thinner to thin up 3~5%.(Excluded use for cleaning) |
˙Equipment
Spray Application
Airless Spray
Brush Roller | Avoid applying the paint in rainy weather or the relative humidity exceed 85%, particularly, a wet surface must be thoroughly dried. All equipment must be cleaned immediately after use. To increase or decrease the usage of thinner depending on the temperature of the coated surface, the temperature decreased may have to add more amount of thinner Pump ratio 30:1 or greater Tip size : 0.017’’~ 0.021’’ Output PSI : 2500~3800 Application by brush is applicable. For special condition please consult with product manufacturer. Application by roller is applicable. For special condition please consult with product manufacturer. |
˙Environment conditions
Condition | Coating | Surface | Environment | Humidity |
Minimum | 10℃ (50℉) | 10℃ (50℉) | 10℃ (50℉) | 30% |
Maximum | 45℃ (113℉) | 60℃ (140℉) | 45℃ (113℉) | 85% |
Industry standards are for substrate temperatures to be 3℃(5℉) above the dew point . the product simply requires the substrate temperature to be above the dew point.
˙Curing Schedule
Surface Temp. & 50% Relative Humidity | Set to touch | Dry hard | Overcoating Intervals (Min) | Overcoating Intervals (Max) |
10℃ (59℉) | 90 minutes | 12 hours | ||
25℃ (77℉) | 30 minutes | 3 hours | 3 hrs | 30 days |
35℃ (95℉) | 20 minutes | 2 hours |
˙Cleanup & Safety
Cleanup
Safety Ventilation | Use No.736 to clean. In case of spillage, absorb and dispose of in accordance with local applicable regulations. Please read and follow all caution statements on this product data sheet and MSDS for this product. Proper ventilation and protective measures must be provided during application and drying to keep solvent vapor concentrations within safe limits and to protect against toxic or oxygen deficient hazards. |
˙Package, Handling & Storage
Shelf Life | 1 years under normal storage conditions |
Shipping Weight
Storage Temperature & Humidity
Flash Point
Storage | 1 Gallon – 8.6kg 5-35℃ (41-95℉) 0-90% Relative Humidity 13℃ (55℉) Avoid sunlight exposure or temperature exceeds 35℃. |