1017 (EP-07) EPOXY WATER TANK COATING

EPOXY WATER TANK COATING

PRODUCT NUMBER

1017 (EP-07)

TYPE

A two-pack, high-build water tank paint based on epoxy resin and special hardener with water resistant pigment.

USES

Used for potable water and fresh water tanks, also suitable for cargo hold, crude oil tanks and ballast tanks etc.

CHARACTERISTICS

1. High build (100µ film can be obtained by one coat spray.)

2. Tough and hard film, outstanding abrasion resistance.

3. Excellent resistance to water, oils and chemicals.

4. Excellent protection against corrosion.

5. No contamination to fresh water.

FINISH

Gloss

COLOR

White, grey or desired colors

MASS DENSITY

Above 1.25 Kg/L (mixture)

VISCOSITY

90~110 KU (mixture, 25℃)

DRYING TIME

Set-to-touch 2 hrs. Dry hard 10 hrs. Fully cured 7 days (25℃)

OPTIMUM FILM THICKNESS

Wet 192 microns Dry 100 microns

THEORETICAL COVERAGE

19.7 ㎡/Gal 5.2 ㎡/L 4.17 ㎡/Kg

OVERCOATING INTERVALS

Min. 20 hrs. Max. 5 days (25℃) or 3 days (30℃)

MIXING RATIO

Base : hardener = 94 : 6 (by wt.)

NON-VOLATILE CONTENT

Above 65% (mixture)

POT LIFE

8 hrs. (mixture, 20℃)

HEAT RESISTANCE

Continuous 93℃

THINNER

No.1005 Epoxy Thinner (SP-12) (only cleaning tools)

THINNING RATE

5~10% (by wt, cleaning tools excluded)

PRECEDING COATS

Steel: No.1006 Epoxy Zinc Rich Primer (EP-03)

No.1075 Epoxy Aluminum Tripolyphosphate Primer

Concrete: No.1073 Epoxy Clear Cement Primer

No.1002 Epoxy Primer, white

STORAGE SHELF LIFE

Minimum 1 year under normal storage conditions.

APPLICATION METHOD

Airless Spray, Brush, Roller

NOTE

1. Mix base and hardener according to the mixing ratio and stir thoroughly then keep static about 10~20 minutes before use.

2. Adhered moisture, grease, dirt, dust, rust and corrosion salts on substrate must be removed thoroughly.

3. Avoid applying the paint in rainy weather or relative humidity exceeded 85%, particularly a wet surface must be thoroughly dried.

4. All equipment must be cleaned immediately after use.

5. The surface of cement wall or cement products must be thoroughly dried then can be applied.

6. When overcoating interval is exceeded, paint surface must be roughened to ensure adhesion.