1076 (EP-66) EPOXY ZINC PHOSPHATE PRIMER

EPOXY ZINC PHOSPHATE PRIMER

PRODUCT NUMBER 1076 (EP-66)

TYPE

A two-pack, anti-corrosive paint based on epoxy resin with zinc phosphate pigment.

USES

Used for the exposed steel structures of petrochemical factory, power plant, coastal facility, storage tank.

CHARACTERISTICS 1. Excellent resistance to sea water.
2. Excellent rust preventive properties.
3. Tough and hard film with very good adhesion.
4. Excellent resistance to mechanical damage.
5. Very good resistance to oils and chemicals

FINISH

Flat

COLOR

White Gray, Brown

FLASH POINT

20℃ (68℉ mixture)

MASS DENSITY

Above 1.3 Kg/L (mixture)

VISCOSITY

70~85 KU (mixture, 25℃)

DRYING TIME Set-to-touch 1 hr.
Dry hard 4 hrs. Fully cured 7 days (25℃)

OPTIMUM FILM THICKNESS

Wet 100~220 microns Dry 45~100 microns

THEORETICAL COVERAGE

37.8 ㎡/Gal 10.0 ㎡/L 7.4 ㎡/Kg (DFT: 45 microns)

OVERCOATING INTERVALS

Min. 8 hrs. (25℃)

MIXING RATIO

Base : Hardener = 92 : 8 (by wt.)

NON-VOLATILE CONTENT

Above 60% (mixture)

POT LIFE

8 hrs. (mixture, 25℃)

THINNER

No.1005 Epoxy Thinner (SP-12)

THINNING RATE

5~15% (by wt.)

PRECEDING COATS

No.908 Wash Primer (SP-01/02)

No.1006 Epoxy Zinc Rich Primer (EP-03)

No.1011 Inorganic Rich Primer (IZ-01)

No.1021 Cathozinc Shop Primer, Type-2 (SP-09)

SP-08 Epoxy Non-Zinc Shop Primer

SUBSEQUENT COATS Epoxy, Vinyl, Chlorinated Rubber or PU system.
FOR AIRLESS SPRAY

Tip Size 0.019"~0.021"

Air Pressure 5~ 6 Kg/cm2

Pump Ratio 28 : 1 or greater

STORAGE SHELF LIFE Minimum 1 year under normal storage conditions.

APPLICATION METHOD

Airless Spray, Brush, Roller.

NOTE

1. Mix base and hardener according to the mixing ratio and stir thoroughly.

2. Avoid applying paint in rainy or humid weather and particularly a wet surface must be thoroughly dried.

3. All equipment must be cleaned immediately after use.

4. When used inside tanks, sufficient ventilation must be provided.