1011 (IZ-01) INORGANIC ZINC RICH PRIMER


INORGANIC ZINC RICH PRIMER

PRODUCT NUMBER

1011 (IZ-01)

TYPE

A two-pack, inorganic zinc rich rust preventive paint based on ethyl silicate and high purity zinc powder

USES

Used for the steel structures of power plants, harbor facility, bridges, water pipelines, storage tanks etc. to long-potent rust prevention.

CHARACTERISTICS

1. Absolutely waterproof, can effectively prevent steel to rust in wet conditions.

2. Excellent resistance to mechanical damage.

3. Unaffected by gas-cutting and welding.

4. Excellent resistance to oils and organic solvents.

5. High corrosion preventive performance, can keep long-potent rust prevent.

6. Superior to CNS 4937 K2088.test specifications, also meet CNS 4936 K2087.

FINISH

Flat

COLOR

Gray

MASS DENSITY

Above 2.4 Kg/L (mixture)

VISCOSITY

70~85 KU (mixture, 25℃)

DRYING TIME

Set-to-touch 15 minutes Dry hard 4 hrs. (25℃)

OPTIMUM FILM THICKNESS

Wet 110 microns Dry 75 microns

THEORETICAL COVERAGE

34.0 ㎡/Gal 9.0 ㎡/L 3.62 ㎡/Kg

OVERCOATING INTERVALS

Min. 24 hrs. Max. 6 months

MIXING RATIO

Base : Zinc dust = 35 : 65 (by wt.)

NON-VOLATILE CONTENT

Above 75% (mixture)


POT LIFE

HEAT RESISTANCE

THINNER

8 hrs. (mixture, 25℃)

Continuous 400℃

No.1012 Inorganic Rich Thinner (SP-13)

THINNING RATE

When the ambient temperature is below 20, use LT-type SP-13 thinner to thin up

3~5%

0~5% (by wt.)

SUBSQUENT COATS

Chlorinated Rubber, Epoxy, Vinyl or PU system

STORAGE SHELF LIFE

Minimum 6 months under normal storage conditions. (Base and zinc dust storage place could not sunlight exposure or temperature exceed 40℃).)

APPLICATION METHOD

Airless Spray

NOTE

1. Pour the zinc dust gradually into the base with constant stirring, and then pass through 80 mesh of filter.

2. When used inside tanks, sufficient ventilation must be provided.

3. The air in the pores will escape through the next coating when overcoating and may cause blister. A mist coat then full coat can reduce this condition:

4. Spray a thin coat to fill the pores in the IZ-01R film, soon after apply to full specified film thickness to break the blisters.

5. Steel surfaces must be blast-cleaned to SIS Sa2 1/2, with moderate roughness (45 ~60 µ).

6. When the relative humidity is lower than 40%, water should be sprayed on after being painted for 30 minutes to promote hardening.

7. The DFT should not exceed 100 microns to avoid cracking.

8. Touch up and repair should be with EP-03 Epoxy Zinc Rich Primer.