No.700 ONE-PACK POLYURETHANE MAINTENANCE PRIMER

ONE-PACK POLYURETHANE MAINTENANCE PRIMER

PRODUCT NUMBER

No.700

TYPE

A one-pack, moist curing type of primer that based on polyisocyanate resin along with rust inhibitors such as zinc powder, flake and rust-converter.

USES

Used on steel structures, bridges, tanks and steel piping for touch-up and rust inhibition.

COLOR

Gray and brown

CHARACTERISTICS

1. One-pack packaging can result to cost-effectiveness and time saving.

2. Moist curing type of coating can be applied under highly humid environment.

3. Excellent permeability to surface due to low viscosity of coating. It can tightly seal and adhere the steel structure surface and its rusty façade.

4. Suitable to the rusty steel surface that can only be cleaned by hand or by high pressure water but is unable to clear by blasting.

5. Exxellent chemicalwater resistance and weatherability.Qualified by the standard of CNS 10757 K6801 3,000 hrs Salt Spray Test.

6. It is fast to dry so as to shorten application period.

COLOR

Brown an gray

HIDING POWER

Above 10 m2/L

WEIGHT

Above 2.2 Kg/L

VISCOSITY 80-100 KU (25℃)
DRYING TIME(25℃) Set-to-touch 30 min.
Dry hard 3 hrs.

OPTIMUM FILM THICKNESS

Wet 100 microns Dry 60 microns


THEORETICAL COVERAGE

38.0 m2/Gal 10.0 m2/L 4.55 m2/Kg

OVERCOATING INTERVALS


Min. 3hrs. Max. 30 days(25℃)

NON-VOLATILES CONTENT Above 70%
THINNER No.736 Thinner
THINNING RATE 0-5% Excluded use for cleaning

PRECEDING COATING

Polyurethane coating, Epoxy series topcoatsYung Flon Topcoat, Toplong Coating.

APPLICATION METHOD

Airless spray, brush or spray

STORAGE SHELF LIFE

Minimum 6 months under normal storage conditions.

NOTE

1. Adhered moisture, grease, and dirt on substrate must be cleaned thoroughly.

2. Using specified thinner to avoid formation of bubble and pinhole.

3. Due to the limit of pot life, once the container is opened, it must be used up within 3 says.

4. Since the paint is easy to react with moisture in air and causes bubble and gelation as a result. Therefore, the container should be tightly closed to avoid the reaction with moisture. After it is opened, the thinner should be added to leftover or to sealed the container so as to prevent the formation of bubbles and gelation.

5. The supervision over application is necessary, because DFT above 80 (microns) in one coat may cause bubble.